Skip to main content
Cardiff City Football Club crestProud to be associatedwith Cardiff City Football Club

Assess First. Recommend Second.

Vaillant ecoTEC sustain Combi

A specification-market combi range with three hot-water labels.

Vaillant ecoTEC sustain Combi boiler
ecoTEC sustain Combi · Official manufacturer product image.

At a glance

Boiler type
Combi · Natural gas
Model output labels
24 kW | 28 kW | 34 kW
Manufacturer range
Specification / project range
Warranty position
Project guarantee duration requires confirmation

Overview

A specification-market combi range with three hot-water labels.

Available outputs

CH means central heating; DHW means domestic hot water. Heating ratings use flow/return water temperatures, not a whole-house sizing formula. Natural-gas figures are shown; no LPG rating is inferred. A cylinder-reheat rating is not instantaneous hot-water delivery.

ecoTEC sustain Combi: verified model ratings
Model / labelCH min–max at 80/60°CCH max at 50/30°CDHW maximumDHW flow at 35°C rise
ecoTEC sustain Combi 24 · 24 kW6.4–18.5 kW20.1 kW24.3 kW9.9 l/min
ecoTEC sustain Combi 28 · 28 kW7.4–18.5 kW20.1 kW28.1 kW11.6 l/min
ecoTEC sustain Combi 34 · 34 kW8.4–18.5 kW19.9 kW34 kW14.1 l/min

Key benefits

A stainless-steel heat exchanger, front servicing access and a modulating burner provide a project-focused combi option. Vaillant also documents hybrid-system compatibility that requires a designed package.

Key takeaway

The three labels change hot-water capacity while the verified heating maximum at 80/60°C stays at 18.5 kW. Project requirements and guarantee terms need confirmation.

Warranty and eligibility

The current specification sources do not establish one universal guarantee period for this range. The project contract and manufacturer registration terms must confirm the duration before quotation. Registration within the manufacturer deadline, correct commissioning, system-water preparation and annual servicing are required. Installer status, eligible protection kit/filter and current manufacturer terms must be confirmed in your written quotation; maximum cover is not automatic. SwiftHeat accreditation is not asserted here.

Keep commissioning, registration and annual-service records. Any extension or paid upgrade is confirmed before purchase and remains subject to current manufacturer terms.

Manufacturer guarantee information for this range

Controls and installation

Vaillant offers eBUS controls and connected-control options. The exact boiler generation, control, gateway, wiring and system accessories must be checked together during assessment; no universal thermostat compatibility is promised.

Manufacturer casing dimensions: 720 × 440 × 338 mm (H × W × D). Working and service clearances are additional.

SwiftHeat assesses fuel, heat loss, hot-water demand, system condition, flue and condensate routing, controls and access before confirming suitability. Assess First. Recommend Second.

Frequently asked questions

What do the ecoTEC sustain Combi output labels mean?

The table separates the manufacturer model label from heating output at 80/60°C, the condensing heating maximum at 50/30°C and any verified DHW or cylinder-reheat rating. Missing figures remain unverified; labels are not substituted for technical ratings.

What guarantee applies to ecoTEC sustain Combi?

The current specification sources do not establish one universal guarantee period for this range. The project contract and manufacturer registration terms must confirm the duration before quotation. Registration within the manufacturer deadline, correct commissioning, system-water preparation and annual servicing are required. Installer status, eligible protection kit/filter and current manufacturer terms must be confirmed in your written quotation; maximum cover is not automatic. SwiftHeat accreditation is not asserted here.

Is ecoTEC sustain Combi suitable for my home?

The three labels change hot-water capacity while the verified heating maximum at 80/60°C stays at 18.5 kW. Project requirements and guarantee terms need confirmation. Suitability depends on the property’s calculated heating and hot-water requirements and must be confirmed following assessment.

Verified manufacturer sources

Checked 2 October 2026. Product generation, availability and terms are reconfirmed when preparing your quotation.

Installation and pricing

The installed price for your selected boiler is confirmed after assessment. The quotation covers the appliance, controls, flue, system preparation and any required pipework. A conversion or relocation can have a different scope from a straightforward replacement.

SwiftHeat’s general starting package

New boiler installations from £1,790 inc. VAT apply to a qualifying standard, straightforward replacement: one bathroom, fewer than 10 radiators and a standard horizontal flue, subject to survey. Specification and warranty selection affect the final cost. This is a general starting offer and is not a price for every model in this catalogue.

Read the starting-package conditions

Humm finance

0% options over 3, 6, 9 or 12 months through Humm Group Limited, subject to application, affordability, eligibility, approval and provider terms. Any applicable deposit, fees and repayment conditions are confirmed during your enquiry/application. Acceptance is not guaranteed.

Finance terms and charges

Qualifying Care+ installations

Two free annual services and a Hive Mini are available on qualifying installations only. Every model is considered under the qualification rules; inclusion in this catalogue does not confirm eligibility. Ask us to confirm the offer in your quotation.

Ask about Care+ eligibility

Ongoing support

Plan the maintenance your appliance requires and keep its service records. If you are considering replacement because of a fault, diagnosis can help establish whether repair is a suitable option first.

Boiler servicing · Repair advice

Installation pricing

Price confirmed following assessment for this configuration. The general New boiler installations from £1,790 inc. VAT offer does not apply to every model or property.

From or indicative prices remain provisional. SwiftHeat issues a written fixed quotation for the agreed scope after the appropriate property and installation assessment, technical checks and warranty-package verification. Remote information gathering may be suitable initially; a home survey is required where the necessary checks cannot be completed remotely.

Your home comes first

We assess heat loss, heating and hot-water requirements, water supply, controls and installation access before recommending an appliance. Bedroom count or a catalogue model number alone cannot establish the right boiler.

Gas Safe registration 978273 · Serving Cardiff, South Wales and across the UK.

Understand suitable boiler types · Start the Boiler Finder · Our installation assessment · Areas we cover